Experimental performance of a string module in a CPC reflector cavity

Document identifier: oai:dalea.du.se:2141
Keyword: Concentrator, Thermal performance, Cost reduction
Publication year: 1998
Relevant Sustainable Development Goals (SDGs):
SDG 9 Industry, innovation and infrastructure
The SDG label(s) above have been assigned by OSDG.ai

Abstract:

The purpose of the work is to develop a cost effective semistationary CPC concentrator for a string PV-module. A novel method of using annual irradiation distribution diagram projected in a north-south vertical plane is developed. This method allows us easily to determine the optimum acceptance angle of the concentrator and the required number of annual tilts. Concentration ranges of 2-5x are investigated with corresponding acceptance angles between 5 and 15°. The concentrator should be tilted 2-6 times per year. Experiments has been performed on a string module of 10 cells connected in a series and equipped with a compound parabolic concentrator with C = 3.3X. Measurement show that the output will increase with a factor of 2-2.5 for the concentrator module, compared to a reference module without concentrator. If very cheap aluminium reflectors are used the costs for the PV-module can be decreased nearly by a factor of two.