Simulation of absolute amplitudes of ultrasound signals using equivalent circuits

Document identifier: oai:DiVA.org:ltu-7742
Access full text here:10.1109/TUFFC.2007.491
Keyword: Engineering and Technology, Electrical Engineering, Electronic Engineering, Information Engineering, Other Electrical Engineering, Electronic Engineering, Information Engineering, Teknik och teknologier, Elektroteknik och elektronik, Annan elektroteknik och elektronik, Signal Processing, Signalbehandling, Industrial Electronics, Industriell elektronik
Publication year: 2007
Relevant Sustainable Development Goals (SDGs):
SDG 3 Good health and wellbeing
The SDG label(s) above have been assigned by OSDG.ai

Abstract:

Equivalent circuits for piezoelectric devices and ultrasonic transmission media can be used to cosimulate electronics and ultrasound parts in simulators originally intended for electronics. To achieve efficient systemlevel optimization, it is important to simulate correct, absolute amplitude of the ultrasound signal in the system, as this determines the requirements on the electronics regarding dynamic range, circuit noise, and power consumption.This paper presents methods to achieve correct, absolute amplitude of an ultrasound signal in a simulation of a pulse-echo system using equivalent circuits. This is achieved by taking into consideration loss due to diffraction and the effect of the cable that connects the electronics and the piezoelectric transducer. The conductive loss in the transmission line that models the propagation media of the ultrasound pulse is used to model the loss due to diffraction.Results show that the simulated amplitude of the echo follows measured values well in both near and far fields, with an offset of about 10%. The use of a coaxial cable introduces inductance and capacitance that affect the amplitude of a received echo. Amplitude variations of 60% were observed when the cable length was varied between 0.07 m and 2.3 m, with simulations predicting similar variations. The high precision in the achieved results show that electronic design and system optimization can rely on system simulations alone. This will simplify the development of integrated electronics aimed at ultrasound systems.

Authors

Jonny Johansson

Luleå tekniska universitet; EISLAB
Other publications >>

Pär-Erik Martinsson

Luleå tekniska universitet; Signaler och system
Other publications >>

Jerker Delsing

Other publications >>

Documents attached


Click on thumbnail to read

Record metadata

Click to view metadata